Nothing
Works: (and
we mean nothing) |
| "Nothing
works" usually is easy for the tech to address.. but
harder for you. Because you FIRST have to check
voltage coming into the spa. If you don't have
experience is using a voltmeter, find someone who
does. You will be dealing with "live" voltage that
can harm you. |
| First
you want to check what voltage you have coming in.
So click WHICH voltage your spa is running on:
|
|
115v |
230v |
|
If voltages are not
correct, have an electrician correct. |
| |
|
If voltages ARE correct,
next step is checking the fuses. Again, a qualified
person should do so.
Fuse
Test |
| |
|
|
If voltage is good and
all the fuses are fine and Nothing works, then you
likely have a failed board. |
|
Easiest way to ID your
board is ID usually on a label or on the board on
the upper left corner of the board. It will be
either the 1042 or 1044 board. See
Board ID Page |
|
Click Here
For Boards |
|
If fuse is blown,
replace. If blows again, then component it protects
probably has failed. On some boards, one of the
smaller fuses is an "air blower" fuse. If that
fails, replace the air blower. On all boards, one
small fuse will protect the board. If that blows,
you had a surge of some type and the fuse tried to
protect the board. If might have or might not have.
|
|
If the larger 20, 25, or
30amp fuse blew, it almost always indicates a pump
motor is failing. If you replace and the problem is
solved, LIKELY, the fuse will blow soon and the time
between fuse blowing will shorten quickly. Replace
the motor or pump/motor complete. |
Any more questions, go to:
Tech Help